Schweitzer Engineering Laboratories Driver Download For Windows

  1. Schweitzer Engineering Laboratories Driver Download For Windows 10
  2. Schweitzer Engineering Laboratories Driver Download For Windows 8.1
  3. Schweitzer Engineering Laboratories Driver Download For Windows 7
  4. Schweitzer Engineering Laboratories Driver Download For Windows Xp

Operating Systems Windows 72 Microsoft Windows Server® 20082 Processor 2.0 GHz dual core processor, GPU-enabled video driver RAM 4 GB Disk Space 100 MB Minimum System Requirements for Diagram Builder Software Making Electric Power Safer, More Reliable, and More Economical Tel: +1.509.332.1890 Email: info@selinc.com Web: www.selinc.com.

  • The SEL Virtual Port Software family includes the following applications: SEL-5827 Virtual Connect Client—Create a temporary serial COM port or Ethernet TCP port for engineering access applications with the SEL-3620 and SEL-3622 Security Gateways.
  • SEL automation controllers support computer configurations with factory-installed Microsoft Windows 10 IoT Enterprise and Windows Server OSs. SEL network and serial port drivers are available to support the installation of other third-party Linux OSs. Third-party supported OS options: Microsoft Windows 10 IoT Enterprise. Microsoft Windows Server.

Schweitzer Engineering Laboratories, Inc. (SEL) is a global supplier of electrical protection products and solutions. The company creates digital products designed to protect, control, monitor, and automate power systems. Founded by Dr. Edmon O. Schweitzer III, the company was incorporated in 1982.

Schweitzer Engineering is headquartered in Pullman, Washington, USA. The company has over 100 offices and more than 5,000 employees worldwide. In early January, Schweitzer released its new SEL-3350 Automation Controller and optimized its Time-Domain Link (TiDL) technology solution.

The SEL-3350 Automation Controller

The SEL-3350 was designed to be compact, flexible, and low-cost. It can be used for dedicated embedded applications requiring mid-level I/O and computation. The device has a 1U form factor, so it can be used when there is limited space.

The controller can be ordered and configured to suit various computer operating systems, including Microsoft Windows 10 internet of things (IoT) Enterprise, Windows Server, and Linux drivers for Ubuntu, CentOS, and Red Hat.

The option to choose between a real-time automation controller (RTAC) and Blueframe operating system will become available to users in 2021’s first quarter. Intelligent electronics device (IED) settings can be viewed and changed, as can report and event data.

Schweitzer engineering laboratories driver download for windows 10

Additionally, not only can diagram drawings and documents be accessed onsite, but the SEL-3350 can also be accessed securely from a remote location through a Microsoft Windows Remote Desktop, a virtual private network (VPN), or Secure Shell (SSH).

The SEL-3350 Automation Controller. Image used courtesy of SEL.

The device features a passive thermal management system and a wide temperature range, meaning the SEL-3350 controller can withstand harsh environments where off-the-shelf computers would fail to function. An error-correcting code (ECC) memory and single-level cell (SLC) solid-state drives (SSDs) have been incorporated into the SEL-3350 to help provide reliable operation in such harsh environments.

For greater protection, a conformal coating can be bought with this device to protect against extreme conditions and airborne contaminants (e.g., hydrogen sulfide, chlorine, salt, and moisture).

The SEL-3350 also meets several standards, including Institute of Electrical and Electronics Engineers (IEEE) 1613, IEEE C37.90, International Electrotechnical Commission (IEC) 61850-3, IEC 60255 protective relay standards, plus IEC 61000-6-2 and IEC 61000-6-4 industrial environment standards.

SEL’s New Merging Unit

Schweitzer released the new SEL-TiDL Merging Unit (TMU) alongside the SEL-3350 Controller in January. This unit combines data sharing, cybersecurity, and protection in one point-to-point digital secondary system. The solution improves safety by taking away high-energy cables from the control house.

Schweitzer Engineering Laboratories Driver Download For Windows 10

The SEL-TMU only needs a single direct fiber connection to a TiDL relay in a control house. No switches or routers are required.

Schweitzer Engineering Laboratories Driver Download For Windows 8.1

The SEL-TMU remote acquisition device is designed to be used in an SEL-TiDL technology system. Image used courtesy of SEL.

The merging unit can digitize analog signals into direct fiber communications. Power system data along with embedded time synchronization can be transported over a fiber-optic cable to an SEL-400 series TiDL relay in the control house. With the ability to transmit data to four TiDL relays, a protection system with a customized topology can be designed.

The stream of data from the SEL-TMU is automatically and independently synchronized to each connected relay, which removes the need for an external time source. The TiDL has an isolated network architecture providing customers with deterministic communications and a more cyber-secure system.

Schweitzer Engineering Laboratories Driver Download For Windows 7

Both the SEL-3350 and SEL-TMU can be utilized for more efficient, safe, and secure monitoring, information, and data exchange within control and power systems.


For lighting, electrical, signage, and technology solutions that allow you to do more call

Schweitzer Engineering Laboratories Driver Download For Windows Xp

EngineeringSverige EnergySchweitzer Engineering Laboratories Driver Download For Windows today at +4(670) 4122522.